Get matched
Homeowner guide

What size air conditioner do I need?

Updated 16 November 20265 minute readUK homes
The short answer

As a starting point, allow about 0.1kW of cooling for each square metre of floor. A 25m² room comes out at about 2.5kW. Sunny rooms, kitchens, high ceilings and busy rooms need more; a well insulated, shady bedroom can need less. Your installer works out the real figure on the visit.

A quick estimate

Measure the floor: length times width gives square metres. Multiply by about 0.1 to get a rough figure in kW.

UK sizing guides put the range at about 0.08kW per m² for quiet, shady rooms up to about 0.15kW per m² for sunny, busy rooms such as kitchens and lounges.

You may also see sizes in BTU. 1kW is about 3,412 BTU an hour, so a 2.5kW unit is about 8,500 BTU.

window 5m 5m 25m² x about 0.1kW 2.5kW a starting point
A 5m by 5m room is 25m². At about 0.1kW per m², that suggests a 2.5kW unit as a starting point.

Typical sizes for typical rooms

Wall units come in set sizes. These are common starting points, not rules.

RoomRough floor areaOften starts at
Small bedroom or studyUp to about 20m²About 2.0 to 2.5kW
Double bedroom or small loungeAbout 20 to 30m²About 2.5kW
Living roomAbout 30 to 40m²About 3.5kW
Open-plan kitchen and living spaceAbout 40 to 60m²About 5kW or more, or two units

What pushes the size up or down

These are the things your installer will look at.

  • Big south or west facing windows: allow more, often 10% to 20%
  • Kitchens and rooms full of computers or screens: allow more
  • High ceilings: more air to cool, so size by volume
  • Lots of people in the room: each extra person adds heat
  • Good insulation and double glazing: you may need less
  • Rooms in the loft or under a flat roof: these get hot, so allow more

Why bigger is not better

Oversizing wastes money

A unit that is too big cools the room fast, switches off, then on again, all day. That uses more energy, wears it out sooner and can leave the room clammy. Undersized is no better: it runs flat out and never quite gets there. That is why sizing needs a proper look at the room.

What happens on the visit

  1. Measuring up

    The installer measures each room and notes the windows, which way they face and the ceiling height.

  2. Working out the load

    They work out how much heat the room gains on a hot day, and loses on a cold one if you want heating too.

  3. Choosing the unit

    They pick a size and type for each room, and say where the indoor and outdoor units will go.

  4. Writing it down

    You get the sizes, models and price in writing, so you can compare quotes like for like.

Checked against

Figures checked on 16 November 2026. Rules and prices change, so your installer will confirm what applies to your home.

FAQs

Quick questions

What size air con do I need for a bedroom?

Most bedrooms start at about 2.0 to 2.5kW. A large or sunny bedroom may need more.

Can one unit cool the whole house?

One wall unit cools one room well. For several rooms, a multi-split runs several indoor units from one outdoor unit, or a ducted system serves a whole floor.

What does kW mean on an air conditioner?

It is how much heat the unit can move each hour, in kilowatts. It is not the electricity it uses, which is much less.

Ready to meet your match?

Two minutes, free, and up to three local installers who will visit, measure up and put a price in writing.

Create my profile